NanoTech Concrete Solutions
Coatings


Flooring Systems

Toll Free
1-800-825-7872

Related Links
Double Wall Tanks

 

Home | About Us | Info Request | CD Catalog | Join Email Updates | Newsletters

lowline chemical tank inventory monitoring

Flowline is the leading source of chemical tank inventory monitoring, automation and safety sensors.

CCSI is proud to offer this most technologically advanced and cost effective solution for the measurement and control of challenging liquid media. Combining our expertise with tank specification and design and Flowline's cutting-edge performance and extreme reliability, we can offer hands-free maintenance for your liquid storage installations.

The MicroSpan ultrasonic transmitter, as shown, is applied in an acetic acid horizontal storage tank. The amazing 2" dead band ensures maximum tank filling capacity. See below for details.

CCSI develops complete storage tank and monitoring solutions, contact with your specifications.

MiniMe Level Transmitter

The MiniMe redefines non-contact ultrasonic level performance in bulk storage tank, day tank and waste sump applications up to 40'. The compact transmitter is the ideal choice for challenging corrosive coating or waste type media. Both versatile and cost effective, MiniMe simply does it all.

MiniMe Specifications:

Range:
0.16' to 40'
Accuracy:
± 0.15% of span
Beam width:
2" / 3" diameter
Dead band:
0.16' / 0.33
Supply voltage:
14-28 VDC
Indication:
LED
Calibration:
Target
Process mount:
1" NPT / 2" NPT
Enclosure rating:
NEMA 6X

Micro-Span Level Transmitter

MicroSpan is the ultimate non-contact ultrasonic level measurement solution for small tank applications including process vessels, IBC totes, waste sumps and 55-gallon drums. The miniature transmitter stands only 1.7" above the tank top and features an incredible 2" dead band for maximum fill capacity.

MicroSpan Specifications:

Range:
0.16' to 4'
Accuracy:
± 0.15% of span
Beam width:
2" diameter
Dead band:
0.16'
Supply voltage:
12-28 VDC
Indication:
LED
Calibration:
Target
Process mount:
1" NPT
Enclosure rating:
NEMA 6X

Switch-Tek™ Optic Leak Detection Switch

The general purpose optic switch is an excellent choice for leak detection in and around secondary containment sumps, tanks and pipes. The sensor can be applied in a broad range of chemical solutions. Media examples include ferric chloride and chlorine. The IA relay provides a reliable switch interface with remote devices such as a PLC, SCADA or alarm. The submersible sensor is universally mounted within the interstitial space of the vessel.

Switch-Tek Specifications:

Orientation:
Universal

Features:

  • PP or PFA Teflon sensor and cable rated NEMA 6X or IP68
  • IA relay selectable NO and NC via power supply wiring polarity
  • Fail-safe sensor inverts wet to alert user for maintenance
Accuracy:
± 1 mm in water
Repeatability:
± 0.5 mm in water
Supply Voltage:
12-36 VDC
Consumption:
25 mA maximum
Contact type:
(1) SPST relay
Contact rating:
120 VAC/VDC @ 1A
(CE: 60 VAC/VDC @ 1A)
Contact output:
Selectable NO/NC
Process temp.:
F: -40° to 194°
C: -40° to 90°
Pressure:
150 psi (10bar) @ 25' C., derated @ 1.667psi (.113 bar) per °C. above 25° C.
Sensor rating:
NEMA 6X (IP68)
Sensor material:

1_ _5: PP
2_ _5: PPA Teflon®

Cable jacket mat.
1_ _5: PP
2_ _5: PPA Teflon®
Cable Type:
4-conductor, #22 AWG (shielded)
Cable length:
Standard: 10' (3m)
Special order: 25' (7.6m) or 50' (12.2
Process mount:
3/4" NPT (3/4" G / Rp)
Mount gasket:
Viton® (G version only)
Classification:
General purpose
Dimensions:
Contact us
CE compliance:
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety

Level Transmitter Universal Panel Meter

The general purpose panel meter provides single tank level indication with optional 4 or 4 relays, 4 or 8 set points and an isolated analog repeater. Each relay can be configured on a single set point switch or latched on two set points for automatic fill or empty control. Package the mete with any of FlowLine level transmitters. LM93 shown at right.

Universal Panel Meter Specifications:

Supply voltage :
120/240 VAC @ 50-60 Hz.

Contact us for full specifications and system configurations.

Consumption:
5 watts maximum
Display type:
LED, 4.5-digit
LED indication:
Relay status
Calibration:
Digital, push button
Linearization:
(11) point function
Memory:
Non-voltile
Sensor input:
(1) two-r three-wire
4-20 mA transmitter
Sensor supply:
24 VDC @ 25 mA

CCSI Double Wall Tanks to complete your liquid storage solution

Now Available

CD Catalog of our complete product line. Includes drawing,
specifications and other content.
Click Here to order.

Tanks | Elast-Liner® | Membranes/Linings | Sealant Products | Coatings
Spill Decks | Flooring | Stormwater Management | Pipe & Tank Repair | Industry Links

© 2000—2010 Chemical Containment Systems Inc. All rights reserved.
Trademarks shown are the property of their respective owners.

TeamEnviro
Chemical Containment Systems is a proud Member of TeamEnviro,
a full spectrum Green consulting group. > More Info

Design & Hosting by